2.6 Reinstall the shaft coupling and/or drive. Remove any shaft
holding or restraining clamps and complete adjustments so that
the shaft is in its nal operating position.
2.7 Install and tighten the vessel ange studs or cap screws to
secure the canister seal assembly to the vessel ange or adapter
plate. Do not over tighten.
2.8 Tighten the set screws in the sleeve drive collar uniformly with an
Allen wrench.
2.9 Remove the setting devices. Save the setting devices and
attachment hardware for future use.
3 Liquid Barrier Supply
The MW-200 Seal design is engineered to operate with a liquid
barrier uid supplied to the seal chamber at a consistent pressure
2 bar (25 psig) above the maximum vessel pressure. Cooling water
may be required to cool the seal chamber. The liquid barrier uid must
be compatible with the process uid. The liquid barrier uid to be used,
maximum vessel pressure, shaft speed, temperature, equipment, and
shaft size must be specied when the seal is ordered. Do not attempt
to use this seal under other conditions without consulting Flowserve.
4 MW-200 Seal Piping
4.1 Install piping for the liquid barrier uid to the canister taps.
A supply tank with a pressure source and pressure gauge are
recommended. Install cooling water piping to the canister cooling
coils if required. See Figure 2.
4.2 Bearings (optional) have been pre-lubricated during seal assembly.