Maintenance – continued –
Torques
All torques are based at 20 °C room temperature.
1. Observe danger note on page 4!
2. Unscrew sealing plug
J and remove strainer H.
3. Clean strainer, sealing plug and gasket seats.
4. Replace strainer and sealing plug in case of visible signs of wear or damage.
5. Replace gasket
I if damaged.
6. Apply heat-resistant lubricant to the thread of the sealing plug (use for instance WINIX
®
2150).
7. Install sealing plug
J with gasket I and strainer H. Tighten sealing plug with a torque
of 120 Nm.
Cleaning / replacing the strainer
Tools
Spanner A. F. 16 mm to DIN 3113, form B
Spanner A. F. 22 mm to DIN 3113, form B
Spanner A. F. 30 mm to DIN 3113, form B
Torque spanner 20 – 120 Nm, ISO 6789
WINIX
®
2150 is a registered trademark of WINIX GmbH, Norderstedt
Item
Designation Torque [Nm]
D
Regulator 090
A
Body screws 025
J
Sealing plug 120