54 DDC-100 Direct-to-Host Programming Guide FCD LMAIM4019-00 FCD LMAIM4019-00 DDC-100 Direct-to-Host Programming Guide 55
System Integrator Tasks
Deliverable From To Comments
Specification Engineer S.I Detail functionality of system
Schedule Contractor S.I. Production Schedule
Manuals Limitorque S.I.
Manuals for DDC-100 Operation:
• LMAIM4019 Direct-to-Host Programming
Guide
• LMAIM1329 Accutronix Installation and
Operation for MX-DDC Field Unit
• LMAIM4029 DDC-100 UEC Field Unit
(Modbus) Installation and Operation Manual
• LMAIM4030 DDC-100 UEC Field Unit Instal-
lation and Commissioning Manual
• LMAIM4022 DDC-100 UEC Field Unit
Wiring and Startup Guidelines
• Modicon Modbus Protocol Reference Guide
PI-MODBUS-300 Rev. G (available from
Modicon)
Hardware for
system development
Contractor S.I.
Hardware may include: DDC-100 Field Units,
RS-232/485 converters
Fourth-Party
Hardware/Software
Component supplier S.I.
Modbus interface modules, Modbus drivers,
non-Limitorque converters, or surge
suppression
Actuator Contractor S.I.
Availability of DDC-100 Field Unit for testing
developed application software
Site Preparation Contractor S.I.
Complete actuator or field unit installation.
Provide actual (as installed) site loop diagram
to System Integrator
Operational System S.I. Contractor
Software only (code) or Hardware and
Software (hardware and code)
Documentation S.I. Contractor
System Operation and Maintenance Manuals,
Operational characteristics of system,
Network Addresses to equipment tag names
Engineer Tasks
Deliverable From To Comments
Specification End-user Engineer Site and system requirements
Schedule End-user Engineer Production Schedule. Completion dates
Sales Support Limitorque Engineer Information on Limitorque products
Manuals Limitorque Engineer
Manuals for DDC-100 Operation:
• LMAIM4019 Direct-to-Host Programming
Guide
• LMAIM1329 Accutronix Installation and
Operation for MX-DDC Field Unit
• LMAIM4029 DDC-100 UEC Field Unit
(Modbus) Installation and Operation Manual
• LMAIM4030 DDC-100 UEC Field Unit Instal-
lation and Commissioning Manual
• LMAIM4022 DDC-100 UEC Field Unit
Wiring and Startup Guidelines
• Modicon Modbus Protocol Reference Guide
PI-MODBUS-300 Rev. G (available from
Modicon)
Project Specification Engineer
Contractor,
S/I, OEM,
Limitorque
Provide operational specifications for all
equipment and service providers
Project Responsi-
bility
Engineer Contractor
Define which supplier is responsible for each
portion of project
P&ID Engineer Contractor
Detailed layout and instructions for building
site. Information should include actuator tag
names, required data points from actuator,
field unit, and field wiring
Site Electrical and
electronics
Engineer Contractor
Detail site electrical requirements, cable type,
layout, and locations. Voltages available for
equipment
Loop Drawings Engineer Contractor
Detail cable routings from Host to each field
device. This defines how the network cable is
to run throughout the facility