NRG 16-11
NRG 17-11
NRG 19-11
Installation Instructions 818578-01
Level Electrode
NRG 16-11, NRG 17-11, NRG 19-11
GESTRA Steam Systems
GESTRA
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - NRG 19-11

1NRG 16-11NRG 17-11NRG 19-11Installation Instructions 818578-01Level Electrode NRG 16-11, NRG 17-11, NRG 19-11GESTRA Steam SystemsGESTRA

Page 2 - Contents

10Functional ElementsFig. 9QRONKLMP

Page 3 - Contents – continued –

11A Measuring electrodeB BoreC SpringD Electrode tipE Disk (measuring surface extension)F Star-lock washerG Set screwH Joint ring 27 x 32, form

Page 4 - Explanatory Notes

12Attention The seating surfaces and threads on the vessel and mounting flange must be accurately machined, Fig. 8 Use GESTRA PN 160 hat flange when

Page 5 - ■ Low level alarm

13Important notes The installation of two low-level limiters in one standpipe is not allowed according to TRD! For the approval of the boiler stan

Page 6 - Technical Data

14Examples of Installation DN 100Fig. 12∅ 2020≥ DN 2024.5 24.520∅ 20Fig. 10Fig. 13 DN 50¾" BSP¾" BSP¾" BSP≤ 20≤ 3000∅ 20≤ 90°∅ 20¾

Page 7 - Technical Data – continued –

151 Flange PN 40, PN 63, PN 160, DN 50, DIN 2501-1 Flange PN 40, PN 63, PN 160, DN 100, DIN 2501-12 For the approval of the boiler standpipe the r

Page 8

16Wiring – continued –Wiring diagramFig. 14Fig. 15This wiring diagram is only valid for France.

Page 9 - Fig. 7 Fig. 8

17Apply mains voltage to level switch NRS 1-7.CommissioningCheck whether the NRG 1…-11 and the associated controller NRS 1-7 are wired in accordance w

Page 10

18Operational MalfunctionsFault-finding list for troubleshootingLevel electrode submerged – low-level alarmFault: Mains voltage is not applied to leve

Page 11

19DisposalDecommissioningRemove the level electrode and separate the waste materials in accordance with the material specification.Electronic componen

Page 12 - Installation

2ContentsUsage for the intended purpose ...

Page 13 - Installation – continued –

20GESTRA AGP. O. Box 10 54 60, D-28054 Bremen Münchener Str. 77, D-28215 BremenTel. +49 (0) 421 35 03 - 0 Fax +49 (0) 421 35 03 - 393E

Page 14 - 24.5 24.5

3WiringNRG 1...-11 ...

Page 15

4Important NotesDangerWhen loosening the electrode steam or hot water might escape. This presents the danger of severe scalds to the whole body.It is

Page 16 - Wiring – continued –

5Explanatory Notes – continued –DescriptionThe level electrode NRG 1...-11 detects the min. liquid level (low level alarm) in a steam boiler. The op

Page 17 - Commissioning

6NRG 16-11, NRG 17-11, NRG 19-11Technical DataType approval TÜV· WB·01-354 EG 01 202 931-B-01-0077Service pressure NRG 16-11: 32 bar at 238 °C NRG 1

Page 18 - Operational Malfunctions

7Corrosion resistanceProvided that the equipment is used for its intended purpose, its safety is not impaired by corrosion.Technical Data – continue

Page 19 - Decommissioning

8Technical Data – continued –DimensionsFig. 4NRG 17-11, NRG 19-11 withoutmeasuring surface extension≤ 150085272Fig. 3NRG 16-11 withmeasuring surface

Page 20 - GESTRA AG

9Fig. 7 Fig. 8N 8N 100.5Fig. 5 ¾" BSP, ISO 228-1∅ 33Design NRG 1...-11AGFBCDEFig. 6IHJS