Electrical Connection – continued –
Wiring diagram OR 52-7
Fig. 4 Shown position of contacts: Alarm 1 and 2, separator OFF and power failure
Notice
Fig. 4 shows an example where the water will be run back to the ship‘s bilge in the event of an alarm
(oil content > 15 ppm) or auxiliary power failure.
With different limit settings alarm contact 1 can, for instance, be used for the first alarm and alarm
contact 2 for the main alarm.
For bilge water monitoring a pneumatic three-way valve can be controlled by the alarm contact 2 via a
solenoid valve. If the turbidity of the effluent is too high (alarm caused by ingress of oil or dirt particles
introduced into the system during start-up) the three-way valve will divert the contaminated water to
the bilge tank. The separation continues until the oil content falls below 15 ppm and the cleaned water
can be discharged overboard.
DS
1 2 23
3
3
3
3 3 3 3
L N
0/4-20mA
R 500
2
2
2
2 2 2 2 2
1
1
1
1 1 1 1 1
S
D
L
Alarm2 Alarm1
ORT 7
Basis
ORG
ORT 7 CPU
A
B
S
Separator
GPS
1
1
2
2
33
key “+” :
Clw - On
key “-” :
Clw - Off
Clw
24VAC
Clw
1
2
2
1
3
4
1
- wire no.
1
2
External wiring Measuring sensor
Disconnecting switch
External
wiring
Purging valve
To first alarm
Attached in housing
cover
Solenoid valve
Three-way valve
Earthing screw
in housing
PE L N
N
L