6.6 Assembly
6.6.1 Reassembly of the MENBLOC unit
REASSEMBLY OPERATIONS
MENBLOC
WITH AN
ADDED
PUMP SHAFT
MENBLOC
WITH AN
EXTENDED
MOTOR
SHAFT
Fit the [2110] pump shaft on
the motor shaft end with its
[6700-01] key
X
Screw and tighten the [6570]
screw in the hole of the motor
shaft end
X
Put the motor vertically shaft
end upwards. Take
precautions not to damage the
fan cover
X X
Put the [9331] shield grid into
the cover for motor casing
X
Mount the lantern bracket
[3180] on the motor. Screw
and tighten the [6577-03] bolts
and the [6581] hexagon nuts
X
Mount the [1221] casing cover
with stuffing box on the [3130]
cover of motor casing and
respect the orientation (the 2
casing cover ribs facing the 2
oblong holes of the cover for
motor casing)
X
Mount the [1221] casing cover
on the [3180] lantern bracket
and respect the orientation
X
For an unclamped casing
cover: screw and tighten the
[6577-02] bolts with an
appropriate wrench tightening
opposing bolts and working
around the casing
X X
Put the fixed ring of the [4200]
mechanical seal into soapy
water and mount it in the
casing cover
X X
Plunge rotating ring into soapy
water
X X
Mount the complete stationary
ring, the spring and the seat of
the [4200] mechanical seal
X X
Mount the [6700] or [6700-02]
key
X X
Mount the [2250] impeller on
the shaft end and avoid
damaging the mechanical seal
seat
X X
Mount the [2905] plain washer.
Screw and tighten the [6570]
screw with an appropriate key
(fix the rotor in position)
X X
REASSEMBLY OPERATIONS
MENBLOC
WITH AN
ADDED
PUMP
SHAFT
MENBLOC
WITH
EXTENDED
MOTOR
SHAFT
Mount the [4590-03] special ring
on the casing cover. Mount the
pump shaft and respect the
orientation
X X
Screw the [6577-01] or [02] bolts.
Tighten opposing bolts working
around the cover with an
appropriate wrench (do not use a
striking-face wrench)
For MENBLOC
80-65-125, 80-65-160, 80-65-200L,
100-80-160, 100-125-250L, the
[6577-01] bolts have to be
mounted with sealing product
LOCTITE pipe sealant 577 or
similar.
X X
Check the correct rotation of the
rotor with an appropriate key at the
shaft end
X X
Reinstall the unit according to the
rules defined in this manual
X X
TO REINSTALL DIRECLY THE ELECTRIC MOTOR
The [6570] screw stays in the shaft
threading but does not hinder the
assembly, install the motor, mount
and block the [6577-03] bolts and
the [6581] nuts
X
Push on the pump shaft end
without shocks or blows until the
pump shaft presses against the
shoulders of the motor shaft.
Tighten the [6570] screw. (see the
following fig. 1)
X
To avoid loosening of the screw
during the running of the pump use
a nut locking compound, after
having pain carefully degreased
the screw and the threading
X
These recommendations correspond to a
complete assembly and to a complete dismantling.
For a partial dismantling, only certain areas will be
relevant.
The torques to be applied are:
Casing / casing Cover /Lantern [6577] Screw [6570]
m.daN
lbf.ft Nm lbf.ft
M10 3 22 " 16 12
M12 5 37 ½" 41 30
M16 11 81 M12 60 44
M14 80 59
M18 120 89
M20 140 103
M24 160 118
Page view 30