Flowserve T-series Thrust Bearing Pot User Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
USER INSTRUCTIONS T-SERIES THRUST BEARING POT ENGLISH 26999907 01-2013
Page 11 of 24 flowserve.com
Non-metallic Bearing Gard™ ll
e) During installation, simply discard any O-ring
material pinched or sheared by the bore. Make
sure the face is perpendicular to the shaft.
f) Once a Bearing Gard™ is in place you may
remove and plug the bearing housing vent.
Bearing Gard™ is self-venting and will not
allow pressure build up in the housing.
Plugging the bearing housing vent will reduce
the entry of contamination into the housing.
g) Refill the bearing housing to the correct oil
level.
4.2.3 General tolerance information
Shaft tolerance: ± 0.05 mm (± 0.002 in.)
Axial run-out: ± 0.075 mm (± 0.003 in.)
Bore tolerance: ± 0.025 mm (± 0.001 in.)
Radial run-out: ± 0.13 mm (± 0.005 in.)
4.3 Optional Lifeseal™ installation
4.3.1 Preparation before installation
a) Check to ensure the housing bore is free from
contaminants, nicks and burrs or sharp edges.
b) Check the shaft and remove any burrs or sharp
edges that may damage the rotary O-ring as
the Lifeseal™ [4330.1] slides over the shaft.
c) Concentricity of the housing bore to the shaft is
to be maintained within 0.13 mm (0.005 in.)
T.I.R.
4.3.2 Lifeseal™ installation
a) Using the water-soluble lubricant provided,
lubricate the stationary unit outside diameter
O-ring and the rotary unit inside diameter O-
ring.
b) Slide the Lifeseal™ [4330.1] along the shaft
and evenly press the unit into the housing bore
until the shoulder on the stationary unit bottoms
out on the face of the housing. During
installation, simply discard any O-ring material
pinched or sheared by the bore. Make sure the
face is perpendicular to the shaft.
c) Evenly tighten the six set screws in the rotary
unit to secure the seal to the shaft.
d) Remove the bronze setting clips and clip bolts
from the Lifeseal™ [4330.1].
4.3.3 General tolerance information
Shaft tolerance: ± 0.05 mm (± 0.002 in.)
Axial run-out: ± 0.075 mm (± 0.003 in.)
Bore tolerance: ± 0.025 mm (± 0.001 in.)
Radial run-out: ± 0.13 mm (± 0.005 in.)
4.4 Thrust bearing pot installation
with optional Bearing
Gard™/Lifeseal™ sealing
Pots are either delivered to the customer fully
assembled except for the oil/cooling piping
extension, or pre-installed in the pump.
Before installation remove all items from the pump
discharge head.
a) Remove any debris and thoroughly clean the
surface receiving the pot and the exposed
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 23 24

Comments to this Manuals

No comments