Flowserve ACE Series Centura User Manual Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
©
2004, Flowserve Corporation, Printed in U.S.A.
3-Position Control/Dribble Control
SR Limit Switch Method
Accord Controls
Installation, Operation and Maintenance Instructions
Flowserve Corporation 1350 N. Mountain Springs Parkway Phone: 801 489-2234
Flow Control Division Springville, Utah 84663-3004 Facsimile: 801 489-2228
www.flowserve.com
FCD ACAIM0075-00 (AC-75) 08/04
Page 8 of 8
Troubleshooting
Problem:
There is power to the unit, but it does not respond.
Solution:
Check the nameplate to see that the correct voltage has
been applied.
Check the wiring to see that it is per the wiring
schematic.
Check the limit switches to see if they are in the normal
operating range.
Check the manual override. If it is in the down position,
the motor is electrically disconnected.
Problem:
Power is getting to the motor, but it merely hums.
Solution:
Check to see that the proper voltage is applied. Make
sure all the connections are tight.
Check to see that the brake coil is pulling the brake pad
and hinge away from the fan.
Check to see that CW and CCW power connections are
not powered at the same time.
Problem:
The actuator performs erratically.
Solution:
Check to see that the actuator is not stalling.
Check the ambient temperature rating. The permanent
split capacitor units are equipped with thermal cut-outs.
Excessive temperatures and cycle frequencies may heat
the motor up and the thermal cut-out turns it off.
Technical Assistance
If actuator is equipped with ESP3 modulating control
card, refer to Bulletin LMP0003-0 for proper connection,
calibration and further troubleshooting guidelines.
** If technical assistance is required,
please have the following information
ready before calling:
A Actuator model number.
B Actuator serial number.
C Actuator sales order number.
D Input signal configuration being used.
Associated Centura IOM’s:
Extra Switch & Heater and Thermostat Installation.
DC Motor Controller Board.
Control Boxes.
Analog output options- Calibration &
Operating Instructions.
Storage Requirements.
Heavy Duty Brake Assembly Kit.
ESP3 Electronic Servo Positioner.
Page view 7
1 2 3 4 5 6 7 8

Comments to this Manuals

No comments