Page 29 of 36 flowserve.com
Viscosity grade ISO 46
Ambient temperature
Bearings temperature 80 °C (176 °F) maximum
TABLE OF EQUIVALENCE AND CHARACTERISTICS
OF RECOMMENDED OILS
MANUFACTURER TYPE
CHARACTERISTICS
BP
ENERGOL
HLP
46
ELF
TURBELF
SA
46
ESSO
TERESSO
46
MOBIL
DTE
MEDIUM
SHELL
TELLUS
T
37
TOTAL
PRESLIA
46
TOTAL
AZOLLA
ZS
46
Density at 15 °C (59 °F) 0.885 0.881 0.868 0.878 0.87 0.872 0.877
Viscosity at 40 °C (104 °F).cSt 45 48.6 43 43 46 46 46
Viscosity at 50 °C (122 °F).cSt 30 31.5 29.4 28 30 29.5 30
Viscosity at 100 °C (212 °F).cSt 6.9 7.1 6.7 7 6.9 6.9 6.8
Pour-point °C / °F - 30 - 22 - 27 - 17 - 12 10.4
- 15 5 - 30 - 22 - 12 10 - 21 - 6
Flash-point °C / °F 210 410 220 428 220 428 220 428 214 417 230 446 230 446
Fire-point °C / °F 240 464 252 486 280 536 240 464 245 473
Aniline point °C / °F 99 210 102 216 110 230 102 216 109 228 101 214 101 214
Viscosity index 105 106 109 105 113 100 100
Acid value 0.2 0.6 0.2 0.13 0.7 0.1 0.7 to 1.2
Color 1 ½ 2 1 2 2 1 ½ 1
Antierosion additives yes yes yes yes yes
Foam inhibitors yes yes yes yes yes yes yes
Anticorrosion additives yes yes yes yes yes yes yes
Antioxidant yes yes yes yes yes yes yes
Conradson carbon residue 0.01 0.2
Limits on temperature °C / °F
- 12 to
120 °C (10
to 248 °F)
- 21 to
110 °C (- 6
to 230 °F)
Saponification < 0.5 1.2
6.2.5 Gland packing
6.2.5.1 Pump fitted with a packed gland
A well run in and correctly adjusted packing gland
requires little maintenance. If, after some time, the
leakage becomes too great, the gland should be
tightened again in order to return these to a normal
level.
If re-tightening is not possible, new packing must be
installed
6.2.5.2 Gland packing inspection and removal
a) Remove the shield guards.
b) Slide back the gland.
c) Remove the packing rings with an extractor
designed for this purpose (including the lantern
ring if it exists; note its position and its direction
of rotation).
d) Inspect the state of the sleeve surface; the
presence of many marked grooves will indicate
that it must be replaced.
e) Carefully clean the different pieces of the
packing gland.
6.2.5.3 Gland packing fitting
If the packing is supplied as cord the packing must
be cut so that the external diameter is lightly
tightened and there is an initial gap between the
sleeve and the packing ring.
For that purpose, wind the packing helically around
the shaft sleeve or a chuck of the same diameter.
(Take precautions to avoid damaging sleeve).
Example of straight cut Example of bevel cut
Ensure a tightening on the stuffing
box housing and not on the sleeve.
SETTING OF PACKING
Page view 28